[Question] How to clean the sensor.
if you want to clean the interior portion of mount (sensor), follow the procedure below.
- 1 Turn on the camera.
- 2 While pushing the macro button
, slide the power switch to [Off].
- The camera should turn off with the shutter left open.
- 3 Like the figure below, hold the mount portion downward, and clean the mount portion using a commercially available blower. Be careful not to drop the camera while cleaning.
- 4 Once done cleaning, turn the power off and then off again.
[Caution]
- • Do not touch the sensor or shutter.
- • The color may fade if the sensor is subjected to intense light for long periods of time. Do not leave the camera with the shutter open.
- • When the [Shutter Initial Sel.] in the Setup menu is set to [Open], the shutter remains open when the power is turned off.
- • Do not use a spray type of blower for cleaning.
- • Do not insert the nozzle of the blower inside part the mount.
- • Damages during cleaning will not be covered by warranty. Be careful not to damaage device while cleaning it.