• Products
  • Store
  • Support

Support and Service

Downloads: Update Software

Digital Camera Utility 5 Update for Windows

Thank you for using PENTAX digital camera.
RICOH IMAGING COMPANY, LTD. wishes to announce the release of the Windows Updater for update the Digital Camera Utility 5. For correct update, you are required to be installed Digital Camera Utility 5 before hand on your PC. Please download the Updater file on your PC first, and update it.

*It is not compatible with previous version of software included Digital Camera Utility 4 / PENTAX PHOTO Browser3 / PENTAX PHOTO Laboratory3.

Name Digital Camera Utility 5 (Version 5.6.2) Windows Updater.
Registered name DCU5Updater_5.6.2.zip (84,709Kbyte)
System requirement OS : Windows 10 / Windows 8.1 (32bit / 64bit) / Windows 8 (32bit / 64bit) / Windows 7 (32bit / 64bit)
CPU : Intel Core2 Duo or higher
Memory : 2.0GB or more
Free disk space : 100MB or more
Monitor: 1280x1024 or more, Can be displayed 24bit full color or more
Objective App. Ver. Digital Camera Utility 5 Version 5.0.0, 5.1.0, 5.2.0, 5.2.1, 5.3.0, 5.4.0, 5.4.1, 5.4.2, 5.5.0, 5.5.1, 5.6.0, 5.6.1
Objective CD-ROM S-SW140, S-SW150, S-SW151, S-SW156, S-SW160, S-SW162, CD-ROM for GRll, S-SW168
Release date 2016/9/7
Copy right RICOH IMAGING COMPANY, LTD.
How to Update
  1. Please download and save the file into appropriate folder on your Hard disk
  2. Double click [DCU5Updater_5.6.2 (Win).zip]. [Win] folder will be appeared.
  3. Double click [Win] folder. [DCU5Updater32_5.6.2.exe] and [DCU5Updater64_5.6.2.exe] are stored in the [Win] folder.
  4. Select either application software that is the same type of your OS (32bit or 64bit).
  5. Copy the application software and paste on desktop.
  6. Double click the application software. The Installer will start, following to the installation display
  7. When the installation will be completed and the massage is displayed, click [Finish].

Changes to V5.6.2
[07. September 2016] Digital Camera Utility 5 (Version 5.6.2) Windows Updater

[Corrections from previous Versions]

  • Corrected - RAW image of K-7 and other previous products cannot develop (include photo print and preview of Laboratory mode) on version 5.6.1.
  • Corrected - When pressing area expanding button on cropping of Laboratory mode, cropping coordinate is out of position.

Changes to V5.6.1
[10. August 2016] Digital Camera Utility 5 (Version 5.6.1) Windows Updater

[Main changes from Version 5.5.1]

  • Corresponded to PENTAX K-70
  • Added new lens name for [HD PENTAX-DA 55-300mm F4.5-6.3 ED PLM WR RE].

[Corrections from previous Versions]

  • Corrected - .When convert the RAW(PEF) format file of Pixel Shift Resolution system to DNG format, shut down incorrectly. (Convert only one standard image)
  • Corrected - .Performance become slow or not performed at some environment of usage.
  • Improved stability for general performance.

Changes to V5.5.1
[28. April 2016] Digital Camera Utility 5 (Version 5.5.1) Windows Updater

[Main changes from Version 5.4.2]

  • Corresponded to PENTAX K-1
  • Added new lens name for
    [HD PENTAX-D FA 15-30mm F2.8 ED SDM WR].
    [HD PENTAX-D FA 28-105mm F3.5-5.6 ED DC WR]
  • Added image finish mode [Flat ] to the Custom Image.
  • Added [ON/OFF ] selection for the Motion Correction function of Pixel Shift Resolution System when developing the RAW- format files

[Corrections from previous Versions]

  • Corrected - When [Photo print] the JPEG images, the re-developed data has been always outputted to the printer.
  • Corrected - The wrong color has been made when re-developed JPEG images.
  • Corrected - The part of the image has been distorted as dot when develop the RAW format file of Pixel Shift Resolution system
  • Corrected – The malfunction such as break the preview image display has been occurred when adjust the parameter for dozens of files
  • Improved other general performance
Changes to V5.4.2
[3, Dec. 2015] Digital Camera Utility 5 (Version 5.4.2) Windows Updater

[Main changes from Version 5.4.1]

  • Added Diffraction Correction on Lens Correction.
    *. For captured image file that is corresponding camera and lens.
  • Added Fringe Correction on Lens Correction.
    *. For captured image file that is corresponding camera and lens.
  • Added ON/OFF setting for RAW development of RRS (Real Resolution System).
  • Added [Recent files] list menu on Laboratory mode.
  • Added new lens name [HD PENTAX-D FA645 35mm F3.5 AL [IF].
  • Added Tone curve inversion reset button. (Easy use for Negative-positive reversal, film duplicator and etc.)
  • Optimize to tone curve of Adobe RGB.
  • Corrected – Miss displayed of highlight correction for before K-5II camera
  • Corrected – Can’t memory input history of address bar on Browser mode.
  • Corrected – When develop RAW image that has been trimmed, Image quality tag is remained RAW.
  • Corrected – Displayed un-printing range on margin setting in print..
  • Corrected – When image transmit in a maximized state from IMAGE Transmitter 2, maximization is released.
  • Corrected – When select “Option” ⇒ “File management” ⇒ “default location” ⇒ “folder at the last saved”, fail in simple image import .
  • Corrected – RAW image develop failure when capture image with changing aspect ratio by K-01.
  • Correspond to compatible reading of parameter file for Windows and Macintosh.
  • Correspond – Windows 10.
Changes to V5.4.1
[11, June 2015] Digital Camera Utility 5 (Version 5.4.1) Windows Updater

[Main changes from Version 5.3.1]

  • Correspond to K-3II
    Synthetic deployment of RRS-RAW
    Added image displayed of RSS information.
  • Correspond to GRII
    Added information to image finish (standard and vivid) for GR.
  • Corrected – when assign odd coordinate on WB gray point setting of RRS-RAW, Gain cannot calculate correctly.
  • Corrected – Horizontal and vertical of quarter assign become reverse on aspect ratio of trimming frame.
  • Corrected – Print page setting is not maintained.
  • Corrected – When displaying camera data for the other manufacturer, aperture value is displayed on capture mode section.
  • Corrected – Reversed M-G axis of WB fine adjustment for image of Q series camera.
  • Corrected – When enlarge thumbnail, different image from captured setting is displayed.
Changes to V5.3.1
[26, March 2015] Digital Camera Utility 5 (Version 5.3.1) Windows Updater

[Main changes from Version 5.2.1]

  • Added lens data
    [HD PENTAX-DA 16-85mmF3.5-5.6ED DC WR]
    [HD PENTAX-DA 18-50mmF4-5.6 DC WR RE]
    [smc PENTAX-DA L18-50mmF4-5.6 DC WR RE]
    [HD PENTAX-D FA★70-200mmF2.8ED DC AW]
    [HD PENTAX-D FA 150-450mmF4.5-5.6ED DC AW]
  • Added display parameter of digital filter history on image data display
  • Added setting value for highlighted clear, drive mode and interval mode on image data display.
  • Added level setting for Peripheral Illumination Correction.
  • Correspond to Image Transmitter 2 connection.(Transfer image automatic display and Thumbnail display)
  • Correspond to K-S2
  • When double-click on the image display and display the image at the 100% magnification, click point become the center of display.
Changes to V5.2.1
[09, October 2014] Digital Camera Utility 5 (Version 5.2.1) Windows Updater

[Main changes from Version 5.0.0]

  • Correspond to 645Z, K-S1 and Q-S1
  • Added lens data
    [HD PENTAX-DA 20-40mmF2.8-4ED Limited DC WR]
    [HD PENTAX-D FA 645 28-45mmF4.5ED AW SR]
  • Corrected ---- Easy image capture is not operated for multiple folders on Windows Vista

[For color fine adjustment]

  • Corrected --- When selecting adjustment color, last selection of adjustment color setting is remained
  • Corrected --- When pressing initialize button, scroll bar and spin edit are not initialized.
  • Corrected --- When performing the multiple image development, captured by AdobeRGB image become sRGB
  • Improved other general performance.
Digital Camera Utility 5 (Windows) Updater Software License Agreement

The customer (hereinafter "the user") shall verify the following items below related to the use of the licensed software supplied to the user by RICOH IMAGING COMPANY, LTD. The download starts when you press "I agree. Start download." on this software license agreement.

  1. Definition of terms
    • Licensed software: "Licensed software" means the captioned program in a format that the user can download from the RICOH IMAGING COMPANY, LTD website or from a site empowered by RICOH IMAGING COMPANY, LTD.
    • Use : "Use" means the user downloading and retrieving the licensed software from the RICOH IMAGING COMPANY, LTD website or from a site empowered by RICOH IMAGING COMPANY, LTD.
    • Designated machine: "Designated machine" means the single computer system set up in order for the user to use the licensed software.
    • Reproduction: "Reproduction" means reproducing the licensed software on a storage device in the same format as the user downloaded or a different format.
    • Modification: "Modification" means performing alternations or making additions to the licensed software, or creating separate software that makes use of all or a portion of the licensed software.
  2. Grant of license
    RICOH IMAGING COMPANY, LTD grants a non-exclusive license to the user on the condition that the user uses the licensed software in accordance with the terms and conditions of this software license agreement. The user may only use the licensed software on the designated machine.
  3. Reproduction of the licensed software
    The user shall not reproduce the licensed software for purposes other than to save and backup the licensed software intended for use on the designated machine.
  4. Modifying the licensed software
    The user shall not modify or reverse engineer the licensed software for any reason.
  5. Property rights and copyright
    The copyright and other property rights for the licensed software and for reproductions of the licensed software belong to RICOH IMAGING COMPANY, LTD regardless of any reason. The user shall not remove the copyright notations from the licensed software or from reproductions of the licensed software.
  6. Grant of sublicense
    The user shall not transfer possession of the licensed software or reproductions of the licensed software to third parties, and the user shall not transfer the license nor grant a sublicense of the licensed software to third parties.
  7. Agreement period
    This software license agreement is effective on the day the user starts using the licensed software and is valid until the time the user stops use. Provided that, when the user has violated any portion of this software license agreement, RICOH IMAGING COMPANY, LTD may revoke the license granted to the user for the licensed software and terminate the software license agreement.
  8. Obligations after termination
    After the software license agreement is terminated, the user, at the user's own responsibility, shall dispose of the licensed software after rendering it into a state where it cannot be used by third parties, and dispose of reproductions and modifications of the licensed software, and all materials related to the licensed software.
  9. Guarantee of the licensed software
    RICOH IMAGING COMPANY, LTD shall not guarantee that the licensed software is suitable for the user's designated purposes, or that the licensed software is useful, or that this licensed software is free from defects, nor shall RICOH IMAGING COMPANY, LTD make any other guarantees related to the licensed software.
  10. Exporting the licensed software
    The user shall not directly or indirectly export all or a portion of the licensed software without obtaining the necessary permission from the Government of Japan or the governments of the relevant countries.
  11. RICOH IMAGING COMPANY, LTD's responsibilities
    RICOH IMAGING COMPANY, LTD A assumes no responsibility under any circumstance for direct or indirect damage or damage from ripple effects that occurs from using the licensed software, for damage to data, programs, or other intangible properties, or for loss of usage benefits and lost profits.
  12. Responsibility for employees
    The user assumes all responsibility that the user's employees (those employees that the user has a responsibility to manage or monitor based on an employment relationship) fully comprehend the obligations set forth in this software license agreement and faithfully fulfill those obligations.

DownloadBack to the flont page

Back to Top